1.
SINGLE
LINE DIAGRAM OF MICROGRID IEEE TEST SYSTEM :
Fig.1 Dynamic Modelling and Control Design for
efficient Power System
Characteristic Features:
·
Micro grid consists of two parts:
ü Solid
State Circuit Breakers
ü Micro-power
supplies (distributed
generations)
·
Sub-station transformer
·
Seven interconnected buses (bus1 is generator bus;
buses 5,6,7 are load buses)
·
Three PMT’s
·
Three breakers
Reason behind the selection of SLD:
·
Due to rapid growth of electricity demand,
grid expansion and several world-wide blackouts, the vulnerability of large
power grids is fully exposed. Therefore the world has now trying to move towards
a new power technology-Distributed Generation i-e DG through micro-grids.
Distributed power generation has outstanding features.
Advantages:
ü flexible power generation
ü Environmental compatibility
ü Better controllability of power system operation
ü Better meet with the power quality
ü Increased reliabilty of consumers
Feasibilty:
·
Micro grid can be installed
in limited area and its results can be studied. Thus its feasible to implement
this on a limited scale first then move towards larger scale.
Cost Analysis:
·
Additional investment is
required in this innovative technique.
·
Cost to benefit ratio must
be calculated before installation.
2.
SINGLE LINE DIAGRAM OF TEST POWER SYSTEM:
Fig.2 Sld of a general power system to study
different power system parameters
Characteristic Features:
·
3-sync.generators 9-bus system 6 lines
·
3 loads 3- two winding t/f
Reasons behind the selection of SLD:
This SLD enables the power
engineer to have a deep eye on the following aspects:-
·
Analyze the dynamic performance of interconnected power systems.
·
Examines the characteristics of the various components of a power system
during normal operating conditions and during disturbances.
·
Explores the detailed
mathematical models of system components and analyzes the system behavior using
the necessary computational tools.
Advantages:
·
Power engineers when finds
out the above information then they are well able to model and operate the
system under the most economical, reliable and in an appropriate manner.
·
Besides consumers are also
directly benefitted.
Feasibilty:
·
This SLD is vey simple and
easy to implement for the different areas of engineering study.
Cost Analysis:
·
Capital required for it is
zero percent. It just requires the determination and will power from the Power
Engineers side.
3. SINGLE LINE
DIAGRAM OF SMALL DISTRIBUTION SYSTEM:
Fig.3 Sld shows a small
distribution system
Characteristic Features:
·
Above sld depicts a small distribution system. The
electric company distributes power at 69kV, which in turn feeds a 13.8kV
distribution system by a 13.8kV, 3-phase, 50-Hz, 20 MVA distribution
transformer with an impedance of 8.5%.
The 1,000kVA, 6.7% impedance transformer
is used to step the voltage down from 13.8kV to 480V.
·
Here the point of study is
the understanding of harmonics generation and harmonic voltage arises due to
it.
·
Keep in mind that PCC stands for “Point of common
coupling”. It is the electrical connecting point or interface
between the utility distribution system and the customer's or user's electrical
distribution system.
Reasons behind the selection of SLD:
·
To improve the “power
quality” is the most in and current
topic of discussion among all the distribution Engineers of the world .
·
Until and unless the
position of harmonics at each and every component of power system is not known
by the engineers then how could they improve the quality of power? Therefore
the above sld is short listed.
Advantages:
It equipped the Distribution Engineers
with the following flow advantages:-
·
Finds the current harmonics
at each and every load in the system.
·
Compare the obtained
results with the IEEE Standards ratings.
·
Harmonics are filter at
each individual load and measured easily at the point PCC.
Feasibilty:
·
Feasibility is 100%
Cost Analysis:
·
Its most economical due to
PCC since no need to measure the harmonic distortion at each and every point
which ultimately saves the capital
4. SLD OF A TEST SYSTEM FOR CONTROLLING STATCOM COMPENSATION:
Fig.4 7-bus electrical network for
the control of frequency through STATCOM/SMES
Characteristic Features:
The load is grouped at bus 7 and consists of an impedance
modeled as a RL load (120MW/32Mvar) supplied by a single generator (250MVA/13.8
kV) and a bulk power system modeled as an infinite bus (10GVA/230kV) by a two
transmission lines. The generator is powered by a multi-stage steam turbine
which is connected to the network through a Y – D step-up transformer (350 MVA, 13.8/230
kV). The STATCOM/SMES i-e static
synchronous compensator and superconducting magnetic energy storage system is
placed at main bus (bus 4) with the purpose of participating in the primary
frequency control of the electric system together with the generator, in case
when severe disturbances are occurred.
Reasons behind selection of this sld:
·
The SLD is selected since
it depicts one of the fundamental concepts of power engineering that is “primary
frequency control mechanism.”A professional Engineer should, infact must know
about the controlling of frequency and its different methods.
Advantages:
·
The knowledge of frequency,
variation in frequency and its control ultimately made the Power Engineers to
safe the precious equipments and power system from massive damage
·
In the meantime consumers
also benefitted directly
·
Security and reliability of
power system is enhanced
Feasibilty:
·
STATCOM /SMES is a new
research
·
Requires experienced and
technically sound persons to be implemented
·
Sincere and serious efforts
required to be implemented in Pakistan
Cost Analysis:
·
Firstly the results can be
judged by installing STATCOM/SMES at certain locations.
·
If desired results are
achieved then can be implemented on large scale
·
Cost of energy storage
devices is not too high so its economically feasible
5. NEUTRAL GROUNDING
RESISTOR:
Fig.5 Sld depicts protection of equipment through
grounding resistor
Characteristic Features:
·
Neutral Grounding Resistors are used to protect power transformers, power generators and otherassociated equipment in your power systems against 50/60 Hz faults (short circuit) and transient phenomena (lightning).
·
Rated current: from 1 amp to 2000 A
·
Rated voltage: from 0.4 to 35kV
·
Rated Resistance: from 1 ohm to 2000 ohm
·
Rated time: 1 sec to continuous time rating
·
All Neutral Grounding Resistors are designed, rated, manufactured and tested in strict
with IEEE32. Routine tests performed on each Neutral Grounding Resistor are measurement of resistance, high voltage power frequency, insulation measurement
·
Standard unit includes the stainless steel resistor assembly plus all the required
insulators, internal connections and hardware installed in a standard safety enclosure. NeutralGrounding Resistor units are completely assembled, prewired, and tested at our facility
Reasons behind the selection of this sld:
·
Protection is a technique where
the world engineers move to and a lot of work is still in progress for the
security of the power system. That’s why the SLD has a right to be short listed
here.
·
Protection is a backbone in
power system. Due to this immense significance this sld is selected.
·
SLD shows in a very simple
manner that how can be a transformer or any equipment can be operated safely.
Advantages:
·
Little amount of initial
investment protects the most precious machines.
·
Consumers are benefitted
directly once again.
Feasibilty:
·
The SLD shown above is much
feasible in its nature.
·
Feasibility of this can be
better judged by experienced engineers at particular location of particular
site either they have to use this or not.
Cost Analysis:
·
Costing PKR=100,000 -10,00,000/-
·
Professionally and
technically its wise to invest this amount in order to safe the most precious
equipments costing millions of rupees.
·
One time initial investment
saves the power system
·
Hence security and
reliability increased
Dear admin you done great job. You share a valuable information about micro grid and power system detailed information is very useful for the analysts who are worked in the power quality analysis filed and Electrical Safety Analysis.We are one of the top safety service providers. We provide services like Arc Flash Analysis, Relay Coordination, Harmonic Analysis, Electrical Safety Audits and other electrical related services. If you have any queries, Please visit Harmonic Analysis